Jackson and Sons has provided full-service residential and commercial heating and air conditioning installation, maintenance tune-ups and repair services in Farmville, NC since 1974.
Read our reviews to learn why your neighbors call us first for their home and business comfort needs in Farmville, NC, then call us at 919-734-9611 to see what we can do for you.
Recent Jobs and Reviews in Farmville, NC
Our Local Reviews by City
- 1, NC (1)
- 7, Beaver Creek, NC (1)
- 9, NC (2)
- Albertson, NC (16)
- Angier, NC (22)
- Atlantic Beach, NC (3)
- Aurora, NC (1)
- Ayden, NC (23)
- Bailey, NC (6)
- Bayboro, NC (3)
- Beaufort, NC (1)
- Benson, NC (12)
- Bentonville, NC (1)
- Bethel, NC (3)
- Beulah, NC (1)
- Beulaville, NC (21)
- Black Creek, NC (2)
- Boon Hill, NC (3)
- Brogden, NC (162)
- Buck Swamp, NC (29)
- Bull Head, NC (1)
- Calypso, NC (5)
- Cary, NC (1)
- Castalia, NC (1)
- Cedar Point, NC (1)
- Chinquapin, NC (3)
- Clayton, NC (161)
- Cleveland, NC (2)
- Clinton, NC (78)
- Contentnea Neck, NC (1)
- Cove City, NC (4)
- Deep Run, NC (30)
- Dover, NC (2)
- Dudley, NC (112)
- Dunn, NC (16)
- Elizabethtown, NC (1)
- Elm City, NC (4)
- Emerald Isle, NC (23)
- Ernul, NC (5)
- Eureka, NC (1)
- Fairfield Harbour, NC (5)
- Faison, NC (37)
- Falling Creek, NC (5)
- Farmville, NC (25)
- Fork, NC (25)
- Four Oaks, NC (67)
- Fremont, NC (142)
- Fuquay-Varina, NC (3)
- Garner, NC (15)
- Godwin, NC (3)
- Goldsboro, NC (4147)
- Grantham, NC (2)
- Great Swamp, NC (1)
- Greenville, NC (162)
- Grifton, NC (13)
- Grimesland, NC (1)
- Harrells, NC (1)
- Havelock, NC (10)
- Hookerton, NC (14)
- Hubert, NC (4)
- Indian Springs, NC (49)
- Institute, NC (5)
- Jacksonville, NC (9)
- Jason, NC (1)
- Kenansville, NC (17)
- Kenly, NC (77)
- Kinston, NC (214)
- Knightdale, NC (10)
- La Grange, NC (289)
- Lillington, NC (4)
- Limestone, NC (1)
- Lucama, NC (4)
- Macclesfield, NC (6)
- Magnolia, NC (3)
- Mar-Mac, NC (20)
- Micro, NC (2)
- Middlesex, NC (2)
- Morehead, NC (2)
- Morehead City, NC (10)
- Moseley Hall, NC (6)
- Mount Olive, NC (191)
- Nashville, NC (14)
- Neuse, NC (1)
- Neuse Forest, NC (1)
- New Bern, NC (188)
- New Hope, NC (38)
- Newport, NC (1)
- Newton Grove, NC (36)
- North Clinton, NC (1)
- O'Neals, NC (1)
- Oriental, NC (1)
- Pikeville, NC (399)
- Pine Level, NC (5)
- Pinetops, NC (1)
- Piney Green, NC (1)
- Piney Grove, NC (2)
- Pink Hill, NC (22)
- Plain View, NC (1)
- Pleasant Grove, NC (3)
- Pollocksville, NC (3)
- Princeton, NC (151)
- Raleigh, NC (2)
- Richlands, NC (2)
- River Bend, NC (3)
- Rocky Mount, NC (56)
- Rose Hill, NC (2)
- Roseboro, NC (6)
- Salemburg, NC (1)
- Salter Path, NC (2)
- Saulston, NC (21)
- Selma, NC (84)
- Seven Springs, NC (100)
- Shine, NC (3)
- Sims, NC (2)
- Smithfield, NC (145)
- Sneads Ferry, NC (2)
- Snow Hill, NC (117)
- Southwest, NC (1)
- Stantonsburg, NC (28)
- Stoney Creek Township, NC (35)
- Swansboro, NC (4)
- Tarboro, NC (8)
- Teachey, NC (1)
- Trent Woods, NC (22)
- Trenton, NC (8)
- Turkey, NC (5)
- Vanceboro, NC (8)
- Wake Forest, NC (2)
- Wallace, NC (5)
- Walnut Creek, NC (45)
- Walstonburg, NC (9)
- Warsaw, NC (32)
- Wendell, NC (10)
- WESLEYAN COL, NC (1)
- Wilders, NC (3)
- Willard, NC (2)
- Willow Spring, NC (2)
- Wilmington, NC (1)
- Wilson, NC (49)
- Wilson Mills, NC (1)
- Winterville, NC (87)
- Zebulon, NC (3)
Job Locations and Reviews
Ricardo T.
Tech washed and mini split and found system to be blowing room temp air. Will need to return to resolve issue customer will give office a call to clear up any confusion on maintenance plan on 2 main systems
Farmville, NC 27828
Landon C.
Tech preformed preventative maintenance and serviced system. Tech recommended maintenance agreement renewal to ensure system is running properly and efficiently. Customer did not invest in renewal at this time. System is up and running with a delta t of 21.
Farmville, NC 27828
Kyle W.
Amanda stated discoloration has been noticed within ceiling tiles located in small server room closet. Inspected drop ceiling supply ducts, and top sides of tiles. No indication of condensation present and ceiling tiles are dry. Discoloration based on location is due to dust accumulation from supply vents. This room is set to cooling at 62 year round and likely has longer runtimes compared to other areas. Will continue to monitor. Unable to pinpoint any challenges at this time besides cosmetic due to dust buildup, which replacing old ceiling tiles would be the solution.
Farmville, NC 27828
Derek J.
Upon arrival tech was shown thermostat was blank and would not adjust. Tech made sure thermostat was receiving proper voltage but still no display. Changed batteries with no results. Installed new Honeywell FP5000 turned power on and thermostat came on. Programmed and started system in heat and cooling with no challenges with system. System is back operational at this time.
Farmville, NC 27828
Chris A.
Upon arrival customer notified tech of ductwork issues and certain rooms aren’t reaching desired tempeture. Tech washed and serviced unit, tech found no issues with unit but did find ductwork to be in rough shape. Tech reccomended replacing ductwork. Customer will wait due to plans to move. Customer will also wait on extending PSA because of moving plans. Tech replaced a 16x20x1. Unit is cooling with a delta T of 17.
Farmville, NC 27828
Chris A.
Tech washed and serviced unit, tech found no challenges at todays visit. Tech recommended hard start kit to lower compressor amps and extend the life of system. Customer not intrested at this time. used a 20x25x1. Unit is heating and cooling properly with a delta T of 18.
Farmville, NC 27828
Dawson M.
Tech serviced unit. Upon arrival customer stated that her only water spicket was taken out. Tech serviced but could not clean condenser. Customer uses rewash-able filters. Tech faced no challenges this visit. Unit is heating and cooling efficiently
Farmville, NC 27828
Romario T.
Tech found no power to the battery power thermostat. Tech found the batteries backwards, tech corrected the batterie polarity and tested the furnace after. Tech did find the suction line insulation touching the flue pipe and the liquid line almost to where it is kinked, tech moved the suction line away from the flue pipe to prevent it from getting hot and causing a challenge. System is operating. Tech received approval from Tim over the phone.
Farmville, NC 27828
Audonel G.
We repair the duct work
Farmville, NC 27828
Review
Alex R.
Took apart drain and ran the snake through the line and cleared out a hairball. Reinstalled the sink P-trap and discovered the sink is draining slow due to pop-up being too low and no way to raise the pop-up any higher. Advised customer about the pop-up being low and customer requested that I leave the pop-up Out so sink drain fast. Left the pop-up with the customer. The sink is draining at proper speed now.
Farmville, NC 27828
Alex R.
Cleared out sink drain and installed a new pop up assembly in the guest bathroom sink.
Farmville, NC 27828
Derek J.
Upon arrival tech checked temperatures for upstairs and downstairs and had a good Delta T reading. Found system cutting out on low temp at zone board when just the upstairs was calling. Low temp set point is as low as it can be set. Tech inspected duct work under house and found a section of the supply has fallen down and blowing air under the house. Tech recommends replacing duct system under house to correct air flow issues first.
Farmville, NC 27828
Matthew L.
Ran the drill snake through the master shower drain and cleared the blockage.
Farmville, NC 27828
Ricardo T.
Bulb replacement.
Farmville, NC 27828
Bryce C.
Upon arrival downstairs was satisfied at thermostat upstairs was calling for cool and only blower was running. Lowered temp even more and unit finally kicked on and only for for 3-5 minutes and cut off. Upstairs zone was still calling for cool when unit cut off. Need tech to see exactly what’s going on with system
Farmville, NC 27828
Ricardo T.
Tech washed and serviced condenser customer did not arrive for tech to service airhandler and check delta t.
Farmville, NC 27828
Ricardo T.
Upon arrival customer stated system not cooling tech pulled a delta t of 16 zone recorded 20+ degree air difference. Previous tech found duct work in poor condition tech attempted to inspect crawlspace but found snake. Tech informed customer about snake and found no other challenges at this time. Will need to return and drop off 14x14x1 filter customer available at anytime.
Farmville, NC 27828
Spencer C.
Tech found condenser fan not running and overheated, compressor was overheated as wel. Compressor capacitor was out of tolerance at 22/35, tech replaced. Tech found fan capacitor was good at 5/5 indicating a failed fan motor tech quoted and replaced motor and found system back up and cooling. Tech found low r22 refrigerant and quoted recharging and adding leak freeze. Tech recommends replacement, but a recharge would have system cooling properly temporarily. Condenser coils are dirty causing high head pressure and inefficiency. Tech quoted cleaning coils. Tech also found there is no ductwork installed and all supply and return air is going straight in and out of the supply and return side of the air handler. System is back operating and suspects system will perform the same as it did before fan failure and informed customer if system is not able to maintain space temperature, recommend repairs or replacement will need to be performed.
Farmville, NC 27828
Joshua C.
Tech returned to repair condensate trap on the Tempstar Gas Pack. Trap repaired, tested and primed. Customer billed out for repair
Farmville, NC 27828
Review
Ricardo T.
Tech washed and serviced unit and found no challenges at this time. System is back up and cooling.
Farmville, NC 27828
Romario T.
Performed ESA. Drain line flushed, filter as provided, checked amp draws and capacitors, cleaned and sanitized coils, washed outdoor unit and tested float switch. No challenges found at this time. Customer renewed contact over the phone with tech. Recommended to have surge protection on the system.
Farmville, NC 27828
Joshua C.
Performed CMA Full Service on 5 rooftop gas package units and 2 split ac systems. No major challenges found today. All electrical tested within spec, and all systems cooling properly. One recommendation the tech had was to replace the condensate trap on the 2014 Tempstar Gas Pack. The trap is currently cracked and water is leaking out instead of flowing out the other end of the trap. Estimate built and picture provided to customer attached fo the summary email. Filters - all filters changed and old ones disposed of.
Farmville, NC 27828
David C.
(XR14) 4TWR4024N1000A
Farmville, NC 27828
Aidan T.
- Tech found batteries installed backward in thermostat. Corrected issue, restoring 24v power and communication. - Confirmed proper amp draws, clean air filter, and capacitor readings. Found outdoor capacitor measuring 29.6/35. Received approval and replaced. - Reinforced exposed thermostat wire running to condenser and secured it to electrical whip. System is now running normally. Thermostat set to 75 at tech departure. System is aged and in poor condition. Advised customer it may need to replaced in the future, pending any costly repairs.
Farmville, NC 27828
Luis R.
Tech found system is low on refrigerant r22. Thermostat reading 75 set to 72 customer informed tech outside was freezing up he turned off now is cooling but struggling. Tech found on previous visit system was low on refrigerant. Tech found suction on 56 psi. Tech recommend replacing system due to age and type of refrigerant.